title: Hermes Gateway Resource Resilience
|
||||
type: runbook
|
||||
status: active
|
||||
created: 2026-07-25
|
||||
updated: 2026-07-25
|
||||
review_after: 2026-10-23
|
||||
verified_on: 2026-07-25
|
||||
version_applies_to: Proxmox CT460
|
||||
confidence: high
|
||||
tags: [hermes, infrastructure, runbook]
|
||||
sources: [live systemd and cgroup v2 state on CT460]
|
||||
---
|
||||
|
||||
# Hermes Gateway Resource Resilience
|
||||
|
||||
## Purpose
|
||||
|
||||
Keep Telegram and the Hermes gateway available when the browser or Web UI
|
||||
causes severe memory pressure inside CT460.
|
||||
|
||||
The observed failure was real: the CT460 memory cgroup OOM-killed a large Web
|
||||
UI process and a Chrome child. Because the gateway previously used
|
||||
`OOMPolicy=stop`, the Chrome child death caused systemd to stop the entire
|
||||
gateway until `Restart=always` brought it back.
|
||||
|
||||
## Active controls
|
||||
|
||||
### Gateway
|
||||
|
||||
File:
|
||||
`/home/hermes/.config/systemd/user/hermes-gateway.service.d/resource-resilience.conf`
|
||||
|
||||
```ini
|
||||
[Service]
|
||||
OOMPolicy=continue
|
||||
MemoryLow=512M
|
||||
CPUWeight=1000
|
||||
```
|
||||
|
||||
The gateway has no `MemoryHigh` or `MemoryMax`. It receives reclaim protection
|
||||
and maximum relative CPU weight, while `OOMPolicy=continue` prevents an
|
||||
OOM-killed browser child from stopping the whole unit. If the main gateway
|
||||
process exits, its existing `Restart=always` policy still restarts it.
|
||||
|
||||
### Camofox
|
||||
|
||||
File:
|
||||
`/home/hermes/.config/systemd/user/camofox-browser.service.d/resource-containment.conf`
|
||||
|
||||
```ini
|
||||
[Service]
|
||||
MemoryHigh=1G
|
||||
MemoryMax=1536M
|
||||
MemorySwapMax=768M
|
||||
OOMPolicy=kill
|
||||
```
|
||||
|
||||
### Hermes Web UI
|
||||
|
||||
File:
|
||||
`/etc/systemd/system/hermes-webui.service.d/resource-containment.conf`
|
||||
|
||||
```ini
|
||||
[Service]
|
||||
MemoryHigh=1G
|
||||
MemoryMax=1536M
|
||||
MemorySwapMax=1G
|
||||
OOMPolicy=kill
|
||||
```
|
||||
|
||||
Camofox and Web UI are allowed to restart under extreme growth instead of
|
||||
consuming most of the container and taking Telegram down with them.
|
||||
|
||||
## I/O priority limitation
|
||||
|
||||
Do not add `IOWeight` to the gateway drop-in unless Proxmox cgroup delegation
|
||||
is changed and verified. CT460 exposes the I/O controller at its top cgroup,
|
||||
but it is not delegated into the container's systemd service tree. Systemd
|
||||
accepts the property, but no live `io.weight` control is created.
|
||||
|
||||
## Health check
|
||||
|
||||
```bash
|
||||
systemctl is-active hermes-webui.service
|
||||
runuser -u hermes -- env XDG_RUNTIME_DIR=/run/user/1000 \
|
||||
systemctl --user is-active camofox-browser.service hermes-gateway.service
|
||||
```
|
||||
|
||||
Check effective limits:
|
||||
|
||||
```bash
|
||||
systemctl show hermes-webui.service \
|
||||
-p OOMPolicy -p MemoryHigh -p MemoryMax -p MemorySwapMax
|
||||
runuser -u hermes -- env XDG_RUNTIME_DIR=/run/user/1000 \
|
||||
systemctl --user show hermes-gateway.service \
|
||||
-p OOMPolicy -p MemoryLow -p MemoryHigh -p MemoryMax -p CPUWeight
|
||||
runuser -u hermes -- env XDG_RUNTIME_DIR=/run/user/1000 \
|
||||
systemctl --user show camofox-browser.service \
|
||||
-p OOMPolicy -p MemoryHigh -p MemoryMax -p MemorySwapMax
|
||||
```
|
||||
|
||||
Expected gateway values include `OOMPolicy=continue`,
|
||||
`MemoryLow=536870912`, `MemoryHigh=infinity`, `MemoryMax=infinity`, and
|
||||
`CPUWeight=1000`.
|
||||
|
||||
## Backups and rollback
|
||||
|
||||
Original source units are backed up at:
|
||||
|
||||
`/home/hermes/.hermes/backups/resource-hardening-20260725/`
|
||||
|
||||
To roll back, remove only these three drop-ins:
|
||||
|
||||
- `resource-resilience.conf` for `hermes-gateway.service`
|
||||
- `resource-containment.conf` for `camofox-browser.service`
|
||||
- `resource-containment.conf` for `hermes-webui.service`
|
||||
|
||||
Then reload the system and user systemd managers and restart only those three
|
||||
services. The original source units were never modified.
|
||||
|
||||